Rfc | 0454 |
Title | File Transfer Protocol - meeting announcement and a new proposed
document |
Author | A.M. McKenzie |
Date | February 1973 |
Format: | TXT, HTML |
Updates | RFC0354 |
Status: | UNKNOWN |
|
Network Working Group A. McKenzie
Request for Comments: 454 BBN
NIC: 14333 16 February 1973
FILE TRANSFER PROTOCOL
Meeting Announcement and a New Proposed Document
Attached is a new proposal for a File Transfer Protocol. The
document is an extensive update to RFC 354 and, I believe,
incorporates solutions to most of the objections to RFC 354.
It now seems appropriate to make another attempt to reach final
agreement on FTP. Accordingly, I am calling a meeting of interested
parties, to be held at BBN on March 16, for discussion of this and
other proposals.
This note is directed to the network community at large, rather than
specifically to the old FTP committee, because I don't believe that
the FTP committee membership includes all the individuals who have
contributed to the current state of FTP design. Nevertheless, it is
intended that the meeting proceed from the current state, rather than
bringing new members up-to-speed. Prospective attendees should
therefore be familiar with at least the following documents:
RFC 354
RFC 385
RFC 414
RFC 418
RFC 438
Anyone wishing to attend this meeting should contact Alex McKenzie
(NIC Ident aam) at BBN, 50 Moulton Street, Cambridge, Mass. 02138.
My telephone number is:
(617) 491-1850 ext.441
When there is some indication of the number of individuals planning
to attend, a meeting room will be reserved and more specific
information will be directed to attendees.
PROPOSED FILE TRANSFER PROTOCOL
This document is the outcome of a meeting held 25 January 1973 in
Cambridge, Massachusetts, by the following people:
Abhay Bhushan (MIT - DMCG)
Bob Bressler (BBN - NET)
Bob Clements (BBN - TENEX)
Alex McKenzie (BBN - NET)
Nancy Neigus (BBN - NET)
Ken Pogran (MIT - MULTICS)
Marc Seriff (MIT - DMCG)
The basis of the document is RFC 354 with considerations drawn from
RFC's 385, 414, 418, and 438 and personal communication with network
participants.
PROPOSED FILE TRANSFER PROTOCOL
INTRODUCTION
The File Transfer Protocol (FTP) is a protocol for file transfer
between HOSTs (including terminal IMPs), on the ARPA Computer Network
(ARPANET). The primary function of FTP is to transfer files
efficiently and reliably among HOSTs and to allow the convenient use
of remote file storage capabilities.
The objectives of FTP are 1) to promote sharing of files (computer
programs and/or data), 2) to encourage indirect or implicit (via
programs) use of remote computers, 3) to shield a user from
variations in file storage systems among HOSTs, and 4) to transfer
data reliably and efficiently. FTP, though usable directly by a user
at a terminal, is designed mainly for use by programs.
The attempt in this specification is to satisfy the diverse needs of
users of maxi-HOSTs, mini-HOSTs, TIPs, and the Datacomputer, with a
simple, elegant, and easily implemented protocol design.
This paper assumes knowledge of the following protocols:
1) The HOST-HOST Protocol (NIC #8246)
2) The Initial Connection Protocol (NIC #7101)
3) The TELNET Protocol (NWG/RFC #318, NIC #9348)
II. DISCUSSION
In this section, the terminology and the FTP model are discussed.
The terms defined in this section are only those that have special
significance in FTP.
II.A Terminology
ASCII The USASCII character set as defined in NIC
#7104. In FTP, ASCII characters are defined to
be the lower half of an eight bit code set (i.e.,
the most significant bit is zero).
access controls Access controls define users' access privileges
to the use of a system, and to the files in that
system. Access controls are necessary to prevent
unauthorized or accidental use of files. It is
the prerogative of a server-FTP process to
provide access controls.
byte size The byte size specified for the transfer od data.
The data connection is opened with this byte
size. Data connection byte size is not
necessarily the byte size in which data is to be
stored in a system, and may not be related to the
structure of data.
data connection A simplex connection over which data is
transferred, in a specified byte size, mode and
type. The data transferred may be a part of a
file, an entire file or a number of files. The
data connection may be in either direction
(server-to-user or user-to-server).
data socket The socket on which a User-FTP process "listens"
for a data connection.
EOF The end-of-file condition that defines the end of
a file being transferred.
EOR The end-of-record condition that defines the end
of a record being transferred.
error recovery A procedure that allows a user to recover from
certain errors such as failure of either HOST
system or transfer process. In FTP, error
recovery may involve restarting a file transfer
at a given checkpoint.
FTP commands A set of commands that comprise the control
information flowing from the user-FTP to the
server-FTP process.
file An ordered set of computer data (including
programs) of arbitrary length uniquely identified
by a pathname.
mode The mode in which data is to be transferred via
the data connection. The mode defines the data
format including EOR and EOF. The transfer modes
defined in FTP are described in Section III.C.
NVT The Network Virtual Terminal as defined in the
ARPANET TELNET Protocol.
NVFS The Network Virtual File System. A concept which
defines a standard network file system with
standard commands and pathname conventions. FTP
only partially embraces the NVFS concept at this
time.
pathname Pathname is defined to be the character string
which must be input to a file system by a user in
order to identify a file. Pathname normally
contains device and/or directory names, and file
name specification. FTP does not yet specify a
standard pathname convention. Each user must
follow the file naming conventions of the file
systems he wishes to use.
record A sequential file may be structured as a number
of contiguous parts called records. Record
structures are supported by FTP but are not
mandatory.
reply A reply is an acknowledgement (positive or
negative) sent from server to user via the TELNET
connections in response to FTP commands. The
general form of a reply is a completion code
(including error codes) followed by an ASCII text
string. The codes are for use by programs and
the text is for human users.
server-FTP process A process or set of processes which perform the
function of file transfer in cooperation with a
user-FTP process. The server-FTP process must
interpret and respond to user commands and
initiate the data connection.
server site A HOST site which has a server-FTP process.
server-TELNET A TELNET process which listens on a specified
socket for an ICP initiated by a user-TELNET, and
performs in accordance with the ARPANET TELNET
Protocol.
TELNET connections The full-duplex communication path between a
user-TELNET and a server-TELNET. The TELNET
connections are established via the standard
ARPANET Initial Connection Protocol (ICP).
type The data representation type used for data
transfer and storage. Type implies certain
transformations between the time of data storage
and data transfer. The representation types
defined in FTP are described in Section III.B.
user A process on behalf of a human being or a human
being wishing to obtain file transfer service.
user site A HOST site satisfying any of the following
conditions: 1) The site where a user is located,
2) a site where a user-FTP process is located, 3)
a site to which a data connection is made by a
server. In the normal case, the sites defined by
1, 2, and 3 are the same site, but nothing in FTP
requires that this be so.
user-FTP process A process or set of processes which perform the
function of file transfer in cooperation with a
server-FTP process. The user-FTP process 1)
initiates the ICP (via a user-TELNET), 2)
initiates FTP commands and 3) "listens" on the
data socket for the data connection. In some
obvious cases (use from TIPs and other mini-
HOSTs) a user-FTP process will be subsumed under
the term "user".
user-TELNET A TELNET process which initiates an ICP to a
specified server-TELNET socket, and performs in
accordance with the ARPANET TELNET protocol.
II.B The FTP Model
With the above definitions in mind, the following model (shown in
Figure 1) may be diagramed for an FTP service.
In the model described in Figure 1, the user-TELNET initiates the
TELNET connections. Standard FTP commands are then generated by the
user and transmitted to the server site via the TELNET connections.
FTP commands are in ASCII, in accordance with NVT conventions and the
TELNET protocol. Note that commands may be initiated by the user
directly through the user-TELNET or via a user-FTP process. Standard
replies are sent from the server to the user in response to the
commands over the TELNET connections.
The FTP commands specify the parameters for the data connection (data
socket, byte size, transfer mode, representation type, and format)
and the nature of file system operation (store, retrieve, append,
delete, etc.). The user-FTP process or its designate should "listen"
on the specified data socket, and it is the server's responsibility
to initiate the data connection and data transfer in accordance with
the specified data connection parameters. It should be noted that
the data socket need not be in the same HOST that initiates the FTP
commands via the TELNET connections, but the user or his user-FTP
process must ensure a "listen" on the specified data socket. A
practical example of such file transfer to third HOSTs is a maxi-HOST
user (who may actually be a TIP user) wishing to transmit a file to
or from an I/O device attached to a TIP. It should also be noted
that two data connections, one for send and the other for receive,
may exist simultaneously.
TELNET
Connections
+-----+ +-------+ +------+ +------+ +-------+ +-----+
| File|<->|Server-|<->|Server|<----------|User |<->|User- |<->|File |
|Sys | |FTP | |TELNET| FTP Cmds |TELNET| |FTP | |Sys- |
| -tem| |Process| | |---------->| | |Process| | tem |
+-----+ | | +------+FTP Replies+------+ | | +-----+
| | | |
| |<------------------------------->|Data |
| | Data Connection(s) |Socket |
+-------+ +-------+
|
|
+------+
| |
| USER |
| |
+------+
Notes: 1. The data connection may be in either direction.
2. The data connection need not exist all of the time.
3. The distinctions between user-FTP and user-TELNET, and
between server-FTP and server-TELNET may not be as
clear-cut as shown above. For example, a user-TELNET may
be directly driven by the user.
FIGURE 1 Model for FTP Use
The protocol requires that the TELNET connections be open while data
transfer is in progress. It is the responsibility of the user to
close the TELNET connections when finished using the FTP service.
The server may abort data transfer if the TELNET connections are
closed.
III. DATA TRANSFER FUNCTIONS
Data and files are transferred only via the data connection. The
transfer of data is governed by FTP data transfer commands received
on the TELNET connections. The data transfer functions include
establishing the data connection to the specified data socket in the
specified HOST (using the specified byte size), transmitting and
receiving data in the specified representation type and transfer
mode, handling EOR and EOF conditions, and error recovery (where
applicable).
III.A Establishing Data Connection
The user site shall "listen" on the specified data socket, prior to
sending a transfer request command. The FTP request command
determines the direction of data transfer, and the socket number (odd
or even) which is to be used in establishing the data connection.
The server on receiving the appropriate store or retrieve request
shall initiate the data connection to the specified user data socket
in the specified byte size (default byte size is 8 bits), and send a
reply indicating that file transfer may proceed. Prior to this
reply, the server should send a reply indicating the server socket
for the data connection. The user may use this server socket
information to ensure the security of his data transfer. The server
may send this reply either before or after initiating the data
connection.
The byte size for the data connection is specified by the BYTE
command. It is not required by the protocol that servers accept all
possible byte sizes. The use of various byte sizes is for efficiency
in data transfer and servers may implement only those byte sizes for
which their data transfer is efficient. It is, however, required
that servers implement at least the byte size of 8 bits.
After the data transfer is completed, it is the server's
responsibility to close the data connection, except when the user is
sending the data. In stream mode the sender must close the data
connection to indicate EOF, i.e., completion of the transfer.
Closing the connection is a server option except under the following
conditions:
1) The server receives an abort command from the user.
2) The socket or the byte size specification is changed by the
user.
3) The TELNET connections are closed.
4) An irrecoverable error condition occurs.
It should be noted that if none of the above conditions occur it is
possible to maintain two simultaneous data connections, for send and
receive.
III.B Data Representation and Storage
Data is transferred from a storage device in sending HOST to a
storage device in receiving HOST. Often it is necessary to perform
certain transformations on the data because data storage representa-
tions in the two systems are different. For example, NVT-ASCII has
different data storage representations in different systems. PDP-10'
s generally store NVT-ASCII as five 7-bit ASCII characters, left-
justified in a 36-bit word. 360's store NVT-ASCII as 8-bit EBCDIC
codes. Multics stores NVT-ASCII as four 9-bit characters in a 36-bit
word. It may be desirable to convert characters into the standard
NVT-ASCII representation when transmitting text between dissimilar
systems. The sending and receiving sites would have to perform the
necessary transformations between the standard representation and
their internal representations.
A different problem in representation arises when transmitting binary
data (not character codes) between HOST systems with different word
lengths. It is not always clear how the sender should send data, and
the receiver store it. For example, when transmitting 32-bit bytes
from a 32-bit word-length system to a 36-bit word-length system, it
may be desirable (for reasons of efficiency and usefulness) to store
the 32-bit bytes right-justified in a 36-bit word in the latter sys-
tem. In any case, the user should have the option of specifying data
representation and transformation functions. It should be noted that
FTP provides for very limited data type representations. Transforma-
tions desired beyond this limited capability should be performed by
the user directly or via the use of the Data Reconfiguration (DRS,
RFC #138, NIC #6715). Additional representation types may be defined
later if there is a demonstrable need.
Data representations are handled in FTP by a user specifying a
representation type. The type may also imply a transfer byte size.
For example, in ASCII representation, the transfer byte size should
be 8 bits, and any other byte size specification will result in
cancellation of the transfer request. In image and Local Byte
representations any byte size is possible. The following data
representation types are currently defined in FTP:
1. ASCII The sender converts data from its internal character
representation to the standard NVT ASCII form. The
receiver converts the data from the standard form to
its own internal form. The data is transferred in
the standard form. The transfer byte size must be 8
bits. This type would be used for transfer of text
files. This is the default type, and it is recom-
mended that this type be implemented by all.
2. EBCDIC The sender transfers data using the EBCDIC character
code and 8-bit transfer byte size. This type may be
used for efficient transfer of EBCDIC files between
systems which use EBCDIC for their internal character
representation.
3. Image The sender transforms data from contiguous bits to
bytes for transfer. The receiver transforms the
bytes into bits, storing them contiguously indepen-
dent of the byte size chosen for data transfer. With
record structure and block mode, the server might
need to pad each record for convenient storage. This
padding is allowed at the end of a record, and should
be remembered by the server so it will be stripped
off when the file is retrieved by the user. The pad-
ding transformation should be well publicized by the
server in case the user processes his file at the
server site. Typical uses for the Image type are
transfer of executable programs between like
machines, and transfer of binary (non-text) data. It
is recommended that this type be implemented by all
for some byte size, preferably including the 8 bit
byte size.
4. Local Byte This representation allows for efficient storage,
use, and retrieval of data. The manner in which data
is to be transformed depends on the byte size for
data transfer, and the particular HOST being used.
The transformation scheme for different byte size is
to be well publicized by all server sites. This
transformation shall be invertible (i.e., if a file
is stored using a certain transfer byte size, an
identical file must be retrievable using the same
byte size and representation type). It is the user's
responsibility to keep track of the representation
type and byte size used for his transfer. Typical
uses of the Local Byte type are in efficient storage
and retrieval of files, and transfer of structured
binary data. This type may be identical to the Image
type for byte size which are integral multiples of or
factors of the computer word length.
Representation type may also be affected by another attribute, the
format. For example, some printers can use ASA (Fortran) vertical
format control procedures to transform printed data of type ASCII or
EBCDIC. Currently format may take one of two values.
1. Unformatted The representation type as specified is unaffected by
any format transformations. This is the default
value.
2. Printfile The server is to transform data of either ASCII or
EBCDIC type in accordance with ASA (Fortran) vertical
format control standards. The data is to be
transferred in 8-bit bytes.
A discussion of the ASA vertical format control appears in NWG/RFC
189, Appendix C, and in Communications of the ACM, Vol. 7, No. 10, p.
606, October 1964. According to the ASA vertical format control
standards, the first character of a formatted record is not printed
but determines vertical spacing as follow:
Character Vertical Spacing before printing
Blank One line
0 Two lines
1 To first line of the next page
+ No advance
In addition to the above four, there are more characters (defined in
Appendix C, RFC 189) which represent an IBM extension to the ASA
standard.
It should be noted that a serving host need not accept all represen-
tation types and/or byte sizes, but it must inform the user request-
ing an unacceptable type or size of this fact by sending an appropri-
ate reply.
III.C. File Structure and Transfer Modes
The only file structures supported directly in FTP at the present
time are record structures. However, the use of record structures is
not mandatory. A user with no record structure in his file should be
able to store and retrieve his file at any HOST. A user wishing to
transmit a record structured file must send the appropriate FTP
'STRU' command (the default assumption is no record structure). A
serving HOST need not accept record structures, but it must inform
the user of this fact by sending an appropriate reply. Any record
structure information in the data stream may subsequently be dis-
carded by the receiver.
All data transfers must end with an EOF. The EOF is defined by the
data transfer mode. For files that have record structures, an EOR is
also defined by the transfer mode. Only the transfer modes and
representation type combinations that have EOR defined may be used
for transfer of files with record structures. Records may be of zero
length but they must be contained in file boundaries. The relation-
ship between files and records is hierarchical but an EOF does not
imply an EOR.
The following data transfer modes are defined in FTP:
1. Stream The file is transmitted as a stream of bytes of the
specified byte size. The EOF is signaled by closing
the data connection. Any representation type and
byte size may be used in the stream mode with file
structure, but use of record structure limits the
type to ASCII or EBCDIC with or without Printfile
format. The convention is that the ASCII character
CR (Carriage Return, Code 15 (octal)) followed by LF
(Line Feed, Code 12 (octal)) indicates an EOR for
ASCII representation type, and the EBCDIC character
NL (New Line, Code 15 (hex)) indicates an EOR for
EBCDIC type. This is the default mode, and it is
recommended that this mode be implemented by all.
2. Text The file is ASCII text transmitted as a sequence of
8-bit bytes in the ASCII representation type, and
optional Printfile format. Record structures are
allowed in this mode. The EOR and EOF are defined by
the presence of special "TELNET-control" codes (,ost
significant bit set to one) in the data stream. The
EOR code is 192 (octal 300, hex CO). The EOF code is
193 (octal 301, hex C1). The byte size for transfer
is 8 bits.
(For ASCII type, text and stream modes are almost identical.)
Comparing the two, the advantages of "stream" mode are:
1) The receiver need not scan the incoming bytes.
2) It is usable with all data types.
and the disadvantages are:
1) Closing the data connection under error conditions can be
misconstrued as an EOF in stream mode when in fact the data
transfer was interrupted. In text mode the EOF is sent expli-
citly.
2) If record structure is specified in stream mode then CRLF
implies EOR, and in order for CRLF to be sent as valid data it
must be transformed, e.g., into CR NUL LF or LF CR.
3. Block The file is transmitted as a series of data blocks
preceded by one or more header bytes. The header
bytes contain a count field, and descriptor code.
The count field indicates the total length of the
data block in bytes, thus marking the beginning of
the next data block (there are no filler bits). The
descriptor code defines last file block (EOF), last
record block (EOR), restart marker (see Section
III.D), or suspect data (i.e., the data being
transferred is suspected of errors and is not reli-
able). Record structures are allowed in this mode,
and any representation type or byte size may be used.
The header consists of the smallest integral number
of bytes whose length is greater than or equal to 24
bits. Only the _least_ significant 24 bits (right-
justified) of header shall have information; the
remaining most significant bits are "don't care"
bits. Of the 24 bits of header information, the 16
low order bits shall represent byte count, and the 8
high order bits shall represent descriptor codes as
shown below.
Integral data bytes >= 24
+---------------+---------------+--------------+
| Don't care | Descriptor | Byte Count |
| 0 to 231 bits | 8 bits | 16 bits |
+---------------+---------------+--------------+
The following descriptor codes are assigned:
Code Meaning
---- -------
0 An ordinary block of data.
1 End of data block is EOR.
2 End of data block is EOF.
3 Suspected errors in data block.
4 Data block is a restart marker.
In the use of block mode it is possible for two or
more conditions requiring different descriptor codes
(suspected errors and either end of record or end of
file) to exist simultaneously. Such a possibility
may be handled by sending a separate EOR or EOF block
with a zero byte count. (This is allowed by the pro-
tocol.)
The restart marker is embedded in the data stream as
an integral number of 8-bit bytes (representing
printable ASCII characters) right-justified in an
integral number of data bytes greater than 8 bits.
For example if the byte size is 7 bits, the restart
marker byte would be one byte right-justified per two
7-bit bytes as shown below:
Two 7-bit bytes
+----------+------------+
| | Marker Char|
| | 8 bits |
+----------+------------+
For byte size of 16 bits or more, two or more marker
bytes shall be packed right-justified. The end of
the marker may be delimited by the character SP (code
32.). If marker characters do not exactly fit an
integral byte, the unused character slots should con-
tain the ASCII character SP (code 32.). For example,
to transmit a six character marker in a 36-bit byte
size, the following three 36-bit bytes would be sent:
+-------------+-------------+---------------+
| Don't care | Descriptor | |
| 12 bits | code=4 | Byte count=2 |
+-------------+-------------+---------------+
+----+---------+---------+--------+---------+
| | Marker | Marker | Marker | Marker |
| | 8 bits | 8 bits | 8 bits | 8 bits |
+----+---------+---------+--------+---------+
+----+---------+---------+--------+---------+
| | Marker | Marker | SP | SP |
| | 8 bits | 8 bits | 8 bits | 8 bits |
+----+---------+---------+--------+---------+
4. Hasp
The file is transmitted as a sequence of 8-bit bytes
in the standard Hasp-compressed data format (document
to be issued by Bob Braden, UCLA). This mode
achieves considerable compression of data for print
files. Record structures are allowed in the Hasp
mode.
The following matrix summarizes the legal combinations of file
transfer parameters. The decimal integers represent legal byte sizes
for each particular STRU-MODE-TYPE-FORM grouping absence of a number
implies illegality. Note that HASP mode is not included since it has
never been defined.
STRU F | R
+-------------------------------+-----+-----+------+
TYPE |\ MODE | | | |
| \ | | | |
| \ S T B | S | T | B |
| FORM +--------+-----+---------+-----+-----+------+
A | U | 8 | 8 | 8 | 8 | 8 | 8 |
| +--------+-----+---------+-----+-----+------+
| P | 8 | 8 | 8 | 8 | 8 | 8 |
----+------+--------+-----+---------+-----+-----+------+
E | U | 8 | | 8 | 8 | | 8 |
| +--------+-----+---------+-----+-----+------+
| P | 8 | | 8 | 8 | | 8 |
----+------+--------+-----+---------+-----+-----+------+
I | U | 1-255 | | 1-255 | | |1-255 |
----+------+--------+-----+---------+-----+-----+------+
L | U | 1-255 | | 1-255 | | |1-255 |
----+------+--------+-----+---------+-----+-----+------+
III.D Error Recovery and Restart
There is no provision for detecting bits lost or scrambled in data
transfer. This issue is perhaps handled best at the NCP level where
it benefits most users. However, a restart procedure is provided to
protect user from system failures (such as failure of either HOST,
FTP-process, or the IMP subnet).
The restart procedure is defined only for the block mode of data
transfer. It requires the sender of data to insert a special marker
code in the data stream with some marker information. The marker
information has meaning only to the sender, but must consist of
printable ASCII characters. The printable ASCII characters are
defined to be octal codes 41 through 176 (i.e., not including codes 0
through 37 and the characters SP and DEL). The marker could
represent a bit-count, a record-count, or any other information by
which a system may identify a data checkpoint. The receiver of data,
if it implements the restart procedure, would then mark the
corresponding position of this marker in the receiving system, and
return this information to the user.
In the event of a system failure, the user can restart the data
transfer by identifying the marker point with the FTP restart pro-
cedure. The following examples illustrate the use of the restart
procedure.
1. When server is the sender of data, the server-FTP process inserts
an appropriate marker block in the data stream at a convenient
data point. The user-FTP process, receiving the data, marks the
corresponding data point in its file system and conveys the last
known sender and receiver marker information to the user. In the
event of system failure, the user or user-FTP process restarts
the server at the last server marker by sending a restart command
with the server's marker code as its argument. The restart com-
mand is transmitted over the TELNET connection and is immediately
followed by the command (such as store or retrieve) which was
being executed when the system failure occurred.
2. When user is the sender of data, the user-FTP process inserts the
appropriate marker block in the data stream. The server-FTP pro-
cess, receiving the data, marks the corresponding data point in
its file system. The server does not store this marker but con-
veys the last known sender and receiver marker information to the
user over the TELNET connections by appropriate reply codes. The
user or the user-FTP process then restarts transfer in a manner
identical to that described in the first example.
IV. FILE TRANSFER FUNCTIONS
The TELNET connections on which FTP commands and replies are
transmitted are initiated by the user-FTP process via an ICP to a
standard server socket. FTP commands are then transmitted from user
to server, and replies are transmitted from server to user. The user
file transfer functions involve sending the FTP commands, interpret-
ing the replies received and transferring data over the data connec-
tion in the specified manner. The server file transfer functions
involve accepting and interpreting FTP commands, sending replies,
setting up the data connection, and transferring data.
IV.A FTP Commands
FTP commands are ASCII strings terminated by the ASCII character
sequence CRLF (Carriage Return followed by Line Feed). The command
codes themselves are ASCII alphabetic characters terminated by the
ASCII character 'space' (octal code 40). For convenience, the com-
mand codes are defined to be four (or less) ASCII alphanumeric char-
acters (including both upper and lower case alphabetic characters).
The command codes and the semantics of commands are described in this
section, but the detailed syntax of commands is specified in Section
V.B, the reply sequences are discussed in Section V.C, and scenarios
illustrating the use of commands are provided in Section V.D.
FTP commands may be partitioned as those specifying access-control
identifiers, data transfer parameters, or FTP service requests. Cer-
tain commands (such as ABOR, STAT, BYE) may be sent over the TELNET
connections while a data transfer is in progress. Some servers may
not be able to monitor the TELNET and data connections simultane-
ously, in which case these commands should be preceded by a TELNET
SYNC to awaken the server. (For other servers this may not be neces-
sary and the SYNC will be ignored.)
IV.A.1 Access Control Commands
The following commands specify access control identifiers (command
codes are shown in parentheses).
User name (USER) - The argument field is an ASCII string identify-
ing the user. The user identification is that which is required
by the server for access to its file system. This command will
normally be the first command transmitted by the user after the
TELNET connections are made (some servers may require this).
Additional identification information in the form of a password
and/or an account command may also be required by some servers.
Servers may allow a new USER command to be entered at any point in
order to change the accounting information. All parameters are
unchanged and any file transfer in progress is completed under the
old account.
Password (PASS) - The argument field is an ASCII string identify-
ing the user's password. This command must be immediatly preceded
by the user name command, and, for some sites, completes the user'
s identification for access control. Since password information
is quite sensitive, it is desirable in general to "mask" it or
suppress type out. It appears that the server has no foolproof
way to achieve this. It is therefore the responsibility of the
user-FTP process to hide the sensitive password information.
Account (ACCT) - The argument field is an ASCII string identifying
the user's account. The command is not necessarily related to the
USER command, as some sites may require an account for login and
others only for specific access, such as storing files. In the
latter case the command may arrive at any time. There are two
reply codes to differentiate these cases for the automaton: When
account information is required for login and the server receives
another command which he buffers, the legal response is reply code
331 when an account is required for a specific transfer requested,
the reply code 433 is returned and the request command is flushed.
Reinitialize (REIN) - This command terminates a USER, flushing all
I/O and account information, except to allow any transfer in pro-
gress to be completed. All parameters are reset to the default
setting and the TELNET connection is left open. A USER command is
expected to follow.
Logout (BYE) - This command terminates a USER and if file transfer
is not in progress, closes the TELNET connection. If file
transfer is in progress, the connection will remain open for
result response and will then close. For "hot card-reader" mode
the REIN command should be used instead.
An unexpected close on the TELNET connection will cause the server
to take the effective action of an abort (ABOR) and a logout
(BYE).
IV.A.2 Transfer Parameter Commands
All data transfer parameters have default values, and the commands
specifying data transfer parameters are required only if the default
parameter values are to be changed. The default value is the last
specified value, or if no value has been specified, the standard
default value as stated here. This implies that the server must
"remember" the applicable default values. The commands may be in any
order except that they must precede the FTP service request. The
following commands specify data transfer parameters
Byte size (BYTE) - The argument is an ASCII-represented decimal
integer (1 through 255), specifying the byte size for the data
connection. The default byte size is 8 bits. The byte size is
always 8 bits in the ASCII and EBCDIC representation types. A
server may reject specific byte size/type combinations by sending
an error reply code in response to a transfer request command.
Data socket (SOCK) - The argument is a HOST-socket specification
for the data socket to be used in data connection. There may be
two data sockets, one from server to user and the other for user
to server data transfer. An odd socket number defines a send
socket and an even socket number defines a receive socket. The
default HOST is the user HOST to which TELNET connections are
made. The default data sockets are (U+4) and (U+5) where U is the
socket number used in the TELNET ICP and the TELNET connections
are on sockets (U+2) and (U+3).
Listen (LSTN) - The argument is a single ASCII character code to
specify the direction of the socket that the server must allocate
for use as a data connection. The server is to "listen" on the
allocated socket when an appropriate transfer command is given.
The following codes are assigned:
S - send
R - receive
Representation Type (TYPE) - The argument is a single ASCII char-
acter code specifying the representation types described in Sec-
tion III.B. The following codes are assigned for type:
A - ASCII
I - Image
L - Local Byte
E - EBCDIC
The default representation type is ASCII.
Format (FORM) - The argument is a single ASCII character code
specifying the formats described in Section III.B. The following
codes are assigned for format:
U - Unformatted
P - Printfile
The default format is Unformatted.
File Structure (STRU) - The argument is a single ASCII character
code specifying file structure described in Section III.C. The
following codes are assigned for structure:
F - File (no ecord structure)
R - Record structure
The default structure is File (ie. no records).
Transfer Mode (MODE) - The argument is a single ASCII character
code specifying the data transfer modes described in Section
III.C. The following codes are assigned for transfer modes:
S - Stream (bytes, close is EOF)
B - Block (header with descriptor and count)
T - Text (TELNET control code for EOR, EOF)
H - Hasp (specially formatted compressed data)
The default transfer mode is Stream.
IV.A.3 FTP Service Commands
The FTP service commands define the file transfer or the file system
function requested by the user. The argument of an FTP service com-
mand will normally be a pathname. The syntax of pathnames must con-
form to server site conventions (with standard defaults applicable),
except that ASCII characters must be used (in conformance with the
TELNET Protocol). The suggested default handling is to use the last
specified device, directory or file name, or the standard default
defined for local users. The command may be in any order except that
a "rename from" command, must be followed by a "rename to" command,
and some servers may require an "allocate" command before a "store"
command. The data, when transferred in response to FTP service
commands, shall always be sent over the data connection. The follow-
ing commands specify FTP service requests:
Retrieve (RETR) - This command achieves the transfer of a copy of
the file specified in the pathname, from server to user site. The
status and contents of the file at the server site shall be unaf-
fected.
Store (STOR) - This command achieves the transfer of a copy of a
file from user to server site. If the file specified in the path-
name exists at the server site, then its contents shall be
replaced by the contents of the file being transferred. A new
file is created at the server site if the file specified in the
pathname does not already exist.
Append (with create) (APPE) - This command achieves the transfer
of data from using to serving site. If the file specified in the
pathname exists at the server site, then the data transferred
shall be appended to that file, otherwise the file specified in
the pathname shall be created at the server site.
Allocate (ALLO) - This command may required by some servers to
reserve sufficient storage to accommodate the new file to be
transferred. The argument field shall be a decimal integer
representing the number of bytes (of size specified by the byte
size command) of storage to be reserved for the file. This
command shall be followed by a store or append command. The ALLO
command should be treated as a NO-OP (no operation) by those
servers which do not require that the maximum size of the file be
declared beforehand.
Restart (REST) - The argument field represents the server marker
at which file transfer is to be restarted. This command does not
cause file transfer but "spaces" over the file to the specified
data checkpoint. This command shall be immediately followed by
the appropriate FTP service command which shall cause file
transfer to resume.
Rename from - (RNFR) - This command specifies the file which is to
be renamed. This command must be immediately followed by a
"rename to" command specifying the new file pathname.
Rename to (RNTO) - This command specifies the new pathname of the
file specified in the immediately preceding "rename from" command.
Together the two commands cause a file to be renamed.
Abort (ABOR) - This command indicates to the server to abort the
previous FTP service command and any associated transfer of data.
The abort command should be preceded by the TELNET SYNCH condition
(indicated by the combination of the DATA MARK and the INS). No
action is to be taken if the previous command has been completed
(including data transfer). The TELNET connections are not to be
closed by the server, but the data connection may be closed. An
appropriate reply should be sent by the server.
Delete (DELE) - This command causes the file specified in the
pathname to be deleted at the server site. If an extra level of
protection is desired (such as the query, "Do you really wish to
delete?"), it should be provided by the user-FTP process.
List (LIST) - This command causes a list to be sent from server to
user site. If the pathname specifies a directory, the server
should transfer a list of files in the specified directory. If
the pathname specifies a file then server should send current
information on the file. A null argument implies the user's
current working or default directory. The data transfer is over
the data connection in type ASCII or type EBCDIC. (It is the user
's responsibility to ensure the correct parameters.)
NList (NLST) - This command causes a directory listing to be sent
from server to user site. The pathname should specify a directory
and the server will return a stream of names of files and no other
information. The data will be transferred in ASCII or EBCDIC type
over the data connection as valid pathname strings separated by
CRLF. This command will allow automatic copying of an entire
directory when used with the appropriate transfer commands.
Status (STAT) - This command shall cause a status response to be
sent over the TELNET connection in form of a reply. The command
may be sent during a file transfer (preceded by a TELNET SYNC) in
which case the server will respond with the status of the opera-
tion in progress, or it may be sent between file transfers. In
the latter case the command may have an argument field such as a
pathname. If the argument is a pathname, the command is analogous
to the "list" command except that data shall be transferred in
ASCII on the TELNET connection. If a partial pathname is given,
the server may respond with a list of file names or attributes
associated with that specification. If no argument is given, the
server should return general status information about the server
FTP process. This should include current values of all transfer
parameters and the status of connections.
Help (HELP) - This command shall cause the server to send helpful
information regarding its implementation status over the TELNET
connection to the user. The command may take an argument (e.g.
any command name) and return more specific information as a
response. The reply is type 100, general system status. It is
suggested that HELP be allowed before entering a USER command.
Mail File (MLFL) - The intent of this command is to enable a user
site to mail data (in form of a file) to another user at the
server site. It should be noted that the files to be mailed are
transmitted via the data connection in ASCII or EBCDIC type. (It
is the user's responsibility to ensure that the type is correct.)
These files should be appended to the destination user's mail by
the server in accordance with serving HOST mail conventions. The
mail may be marked as sent from the particular using HOST and the
user specified by the 'USER' command. The argument field may con-
tain one or more system or NIC idents (it is recommended that mul-
tiple ident be allowed so the same mail can easily be sent to
several users), or it may be empty. If the argument field is
empty or blank (one or more spaces), then the mail is destined for
a printer or other designated place for site mail. A NIC ident
refers to the standard identification described in the NIC Direc-
tory of Network Participants. A serving host may keep a table
mapping NIC indents into system idents, although NIC idents are
not required in the implementation. A system ident is the user's
normal identification at the serving host. The use of system
idents would allow a network user to send mail to other users who
do not have NIC identification but whose system ident is known.
Mail (MAIL) - This command allows a user to send mail that is not
in a file over the TELNET connection. The argument field may con-
tain one or more system or NIC idents, or it may be empty. The
idents are defined as above for the MLFL command. After the
'MAIL' command is received, the server is to treat the following
lines as text of the mail sent by the user. The mail text is to
be terminated by a line containing only a single period, that is,
the character sequence ".CRLF" in a new line. It is suggested
that a modest volume of mail service should be free; i.e., it may
be entered before a USER command.
IV.A.4 Miscellaneous Commands
NoOP (NOOP) - This command does not affect any parameters or pre-
viously entered command. The server simply sends a no-op reply.
Quote (QUOT) - This command allows the user to talk directly to
the FTP-server. After parsing this command, the user-FTP process
will pass without examination all succeeding liners until the NQUO
command is received. Between these two commands the server will
respond appropriately to his implementation and the user's
requests.
NoQuote (NQUO) - This command returns the user and server
processes to normal interactive mode. Both QUOT and NQUO have
reply codes to be sent by th server process to the user process to
ensure agreement on the current mode.
The quote commands provide a convenient method of testing server-
implemented experimental commands. The names of the latter should
begin with an X, and can be listed in the system HELP reply. It
should be noted that the official command set is expandable; sugges-
tions should go first to Alexander A. McKenzie (BBN).
IV.B FTP Replies
The server sends FTP replies over the TELNET connection in response
to user FTP commands. The FTP replies constitute the acknowledgment
or completion code (including errors). The FTP-server replies are
formatted for human or program interpretation. Single line replies
consist of a leading three-digit numeric code followed by a space,
followed by a one-line text explanation of the code. For replies
that contain several lines of text, the first line will have a lead-
ing three-digit numeric code followed immediately by the ASCII char-
acter "-" (Hyphen, Code 55 (octal)) and possibly some text. All
succeeding continuation lines except the last are constrained not to
begin with three digits; the last line must repeat the numeric code
of the first line and be followed immediately by a space.
For example:
100-First Line
Continuation Line
Another Line
100 Last Line
The numeric codes are assigned by groups and for ease of interpreta-
tion by programs in a manner consistent with other protocols such as
the RJE protocol. The three digits of the code are to be interpreted
as follows:
a) The first digit specifies type of response as indicated below:
000 These replies are purely informative and constitute neither a
positive nor a negative acknowledgment.
1xx Informative replies to status inquiries. These constitute a
positive acknowledgment to the status command.
2xx Positive acknowledgment of previous command or other success-
ful action.
3xx Incomplete information. Activity cannot proceed without
further specification and input.
4xx Unsuccessful reply. The request is correctly specified but
the server is unsuccessful in correctly fulfilling it.
5xx Incorrect or illegal command. The command or its parameters
were invalid or incomplete from a syntactic viewpoint, or the
command is inconsistent with a previous command. The command
in question has been completely ignored.
6xx-9xx Reserved for future expansion.
b) The second digit specifies the general category to which the
response refers:
x00-x29 General purpose replies, not assignable to other
categories.
x30 Primary access. Informative replies to the "log-on" attempt.
x40 Secondary access. The primary server is commenting on its
ability to access a secondary service.
x5x FTP results
x6x RJE results.
x7x-x9x Reserved for future expansion.
c) The final digit specifies a particular message type. Since the
code is designed for an automation process to interpret, it is
not necessary for every variation of a reply to have a unique
number. Only the basic meaning of replies need have unique
numbers. The text of a reply can explain the specific reason for
that reply to a human user.
Each TELNET line delimited by a numeric code and CRLF (or group
of text lines bounded by coded lines) that is sent by the server
is intended to be a complete reply message. It should be noted
that the text of replies is intended for a human user. Only the
reply codes and in some instances the first line of text are
intended for programs.
The assigned reply codes relating to FTP are:
000 General information message (site, time of day, etc.).
010 Message from system operator.
030 Server availability information.
050 FTP commentary or user information.
100 System status reply.
110 System busy doing...
150 File status reply
151 Directory listing reply.
200 Last command received correctly.
201 An ABORT has terminated activity, as requested.
202 Abort request ignored, no activity in progress.
230 User is "logged in". May proceed.
231 User is "logged out". Service terminated.
232 Logout command noted, will complete when transfer done.
233 User is "logged out". Parameters reinitialized.
250 FTP file transfer started correctly.
251 FTP Restart-marker reply.
Text is : MARK yyyy = mmmm
where yyyy is user's data stream marker (yours)
and mmmm is server's equivalent marker (mine)
(Note the spaces between the markers and '=')
252 FTP transfer completed correctly.
253 Rename completed.
254 Delete completed.
255 FTP server data socket reply
Text is: SOCK nnnn
where nnnn is a decimal integer representing
the server socket for data connection
256 Mail completed.
300 Connection greeting message, awaiting input.
301 Current command incompleted (no CRLF for long time).
330 Enter password
331 Enter account (if account required as part of login
sequence).
350 Enter mail, terminate by a line with only a '.'
400 This service not implemented.
401 This service not accepting user now, goodbye.
430 Log-on time or tries exceeded, goodbye.
431 Log-on unsuccessful. Usre and/or password invalid.
432 User not valid for this service.
433 Cannot transfer files without valid account. Enter account.
434 Log-out forced by operator action. Phone site.
435 Log-out forced by system problem.
436 Service shutting down, goodbye.
450 FTP: File not found.
451 FTP: File access denied to you.
452 FTP: File transfer incomplete, data connection closed.
453 FTP: File transfer incomplete, insufficient storage space.
454 FTP: Cannot connect to your data socket.
455 FTP: File system error not covered by other reply codes.
456 FTP: Name duplication rename failed.
457 FTP: Transfer parameters in error.
500 Last command line completely unrecognized.
501 Syntax of last command is incorrect.
502 Last command incomplete, parameters missing.
123456789012345678901234567890123456789012345678901234567890123456789012
503 Last command invalid (ignored), illegal parameter combination.
504 Last command invalid, action not possible at this time.
505 Last command conflicts illegally with previous command(s).
506 Requested action not implemented by the server.
507 Catchall error reply.
550 Bad pathname specification (e.g., syntax error).
V. DECLARATIVE SPECIFICATIONS
In order to make FTP workable without needless error messages, the
following minimum implementation is required for servers:
TYPE -- ASCII (with 8-bit bytes)
MODE -- Stream
STRUCTURE -- File
Record (with ASCII type and CRLF for EOR)
FORM -- Unformatted
COMMANDS -- USER, BYE, SOCK
TYPE, BYTE, MODE, STRU, FORM
for the default values
RETR, STOR
NOOP
The initial default values for transfer parameters are:
TYPE -- ASCII
BYTE -- 8
MODE -- Stream
STRU -- File
FORM -- Unformatted
V.A Connections
The server-FTP process at the server site shall "listen" on Socket 3,
via its server-TELNET. The user or user-FTP process at the user site
shall initiate the full-duplex TELNET connections via its user-TELNET
performing the ARPANET standard initial connection protocol (ICP) to
server socket 3. Servers may specify that interaction over the TEL-
NET connections be line-at-a-time with local echo. The server is not
obliged to provide remote echo and may ignore TELNET control charac-
ters; he should not, however, return error response to the latter.
All editing of command lines similarly must be local. The TELNET
connections shall be closed by the user site upon completion of use
and receipt of the last server reply.
The user site must "listen" on the specified data socket or sockets
(a send and/or a receive socket). The server site shall initiate the
data connection using the specified data socket and byte size. The
direction of data connection and the data socket used shall be
determined by the FTP service command. The server shall send a reply
to the user indicating the server data socket so that the user may
ensue the security of data transfer. This can be done at any time
prior to the first transfer of data over a data connection. It
should be emphasized that the user-FTP should not wait for a 255
(server data socket) reply before doing the "listen", since there is
no guarantee that the reply will arrive before the user site receives
the initiating RFC. The security check can be done when the reply
arrives and the data connection closed if it was made to a socket
other than the one specified.
The data connection shall be closed by the server site under the con-
ditions described in Section III.A. If the server wishes to close
the connection in modes where that is not required, it is recommended
that the close be sent immediately after the file transfer is com-
pleted rather than after a new transfer command is received, because
the user or server may have to test the state of the socket before
doing a "listen" or "init". The server should in general send a
reply before closing the data connection to avoid problems at the
user end, though, for reasons stated above, the user-FTP should not
wait for the reply before doing his close.
V.B Commands
The commands are ASCII character strings transmitted over the TELNET
connections as described in section IV.A. The command functions and
semantics are described in sections IV.A.1, IV.A.2, IV.A.3, and
IV.A.4. The command syntax is specified here.
The commands begin with a command code followed by an argument field.
The command codes are four or less ASCII alphabetic characters.
Upper and lower case alphabetic characters are to be treated identi-
cally. Thus any of the following may represent the retrieve command:
RETR Retr retr ReTr rETr
This also applies to any symbols representing parameters values, such
as A or a for ASCII TYPE. The command codes and the argument fields
are separated by one or more spaces.
The argument field consists of a variable length ASCII character
string ending with the character sequence CRLF (Carriage Return
immediately followed by Line Feed). In the following section on syn-
tax it should be stressed that all characters in the argument field
are ASCII characters. Thus a decimal integer shall mean an ASCII
represented decimal integer.
The following are all the currently defined FTP commands:
USER <username> CRLF
PASS <password> CRLF
ACCT <acctno> CRLF
REIN CRLF
BYE CRLF
BYTE <byte size> CRLF
SOCK <HOST-socket> CRLF
LSTN <direction> CRLF
TYPE <type code> CRLF
FORM <form code> CRLF
STRU <structure code> CRLF
MODE <mode code> CRLF
RETR <pathname> CRLF
STOR <pathname> CRLF
APPE <pathname> CRLF
ALLO <decimal integer> CRLF
REST <marker> CRLF
RNFR <pathname> CRLF
RNTO <pathname> CRLF
ABOR CRLF
DELE <pathname> CRLF
LIST <pathname> CRLF
NLST <pathname> CRLF
STAT <pathname> CRLF
HELP <string> CRLF
MLFL <users> CRLF
MAIL <users> CRLF
NOOP CRLF
QUOT CRLF
NQUO CRLF
The syntax of the above argument fields (using BNF notation where
applicable) is:
<username> ::= <string>
<password> ::= <string>
<acctno> ::= <string>
<string> ::= <empty>/<char>/<char><string>
<char> ::= any of the 128 ASCII characters except CR and LF.
<marker> ::= <pr string>
<pr string> ::= <empty>/<pr char>/<pr char> <pr string>
<pr char> ::= any ASCII code 33 through 126
<byte size> ::= any decimal integer 1 through 255.
<HOST-socket> ::= <socket>/HOST number>,<socket>
<HOST number> ::= a decimal integer specifying an ARPANET HOST
<socket> ::= decimal integer between 0 and (2**32)-1
<direction> ::= S/R
<form code> ::= U/P
<type code> ::= A/E/I/L
<structure code> ::= F/R
<mode code> ::= S/B/T/H
<pathname> ::= <string>
<decimal integer> ::= <digit>/<digit><decimal integer>
<digit> ::= 0|1|2|3|4|5|6|7|8|9
<empty> ::= the null string (specifies use the default).
<users> ::= <user>|<user,<users>
<user> ::= <empty>|<NIC ident>|<sys ident>
<NIC ident> ::= <string>
<sys ident> ::= <string>
V.C Sequencing of Commands and Replies
The communication between the user and server is intended to be an
alternating dialogue. As such, the user issues an FTP command and
the server responds with a prompt primary reply. The user should
wait for this initial primary success or failure response before
sending further commands.
A second type of reply is sent asynchronously with respect to user
commands. These replies may, for example, report on the progress or
completion of file transfer and as such are secondary replies to file
transfer commands.
The third class of replies are informational and spontaneous replies
which may arrive at any time. These replies are listed below as
spontaneous.
COMMAND-REPLY CORRESPONDENCE TABLE
COMMAND SUCCESS FAIL
------- ------- ----
USER 230,330 430-432,500-505,507
PASS 230,331 430-432,500-507
ACCT 230 430-432,500-507
REIN 232,233 401,436,500-507
Secondary Reply 300
BYE 231,232 430-432,500-505,507
BYTE 200,331 500-507
SOCK 200,331 500-505,507
LSTN 255,331 500-507
TYPE 200,331 500-507
FORM 200,331 500-507
STRU 200,331 500-507
MODE 200,331 500-507
RETR 250,331 433,450,451,454,455,500-505,507,550
Secondary Reply 252 452
STOR 250,331 433,451,454,455,457,500-505,507,550
Secondary Reply 252 452,453
APPE 250,331 433,451,454,455,457,500-507,550
Secondary Reply 252 452,453
ALLO 200,331 500-507
REST 200,331 500-507
RNFR 200,331 433,450,451,455,500-507,550
RNTO 253,331 433,450,451,455,456,500-505,507,550
ABOR 201,202,331 500-507
DELE 254,331 433,450,451,455,500-507,550
LIST 250,331 433,450,451,454,455,457,500-507,550
Secondary Reply 252 452
NLST 250,331 433,450,451,454,455,457,500-507
Secondary Reply 252 452
STAT 100,110,150, 450,451,454,455,500-507,550
151,331
HELP 000,030,050, 500-507
331
MLFL 250,331 433,450,451,454,455,457,500-507
Secondary Reply 252 452,453
MAIL 331,350 433,450,451,455,500-507
Secondary Reply 256
NOOP 200 500-505,507
QUOT 200,331 500-507
NQUO 200 500-505,507
Spontaneous 0xx,300,301 400,401,434-436
Replies 251,255
V.D Typical FTP Scenarios
1. TIP User wanting to transfer file from HOST X to local printer:
a) TIP user opens TELNET connections by ICP to HOST X, socket 3.
b) The following commands and replies are exchanged:
TIP HOST X
--- ------
USER username CRLF ---------->
<----------330 Enter Password CRLF
PASS password CRLF ---------->
<----------230 User logged in CRLF
SOCK 65538 CRLF ---------->
<----------200 Command received OK CRLF
RETR this.file CRLF ---------->
<----------255 SOCK 5533 CRLF
(HOST X initiates data connection to
TIP socket 65538, i.e., PORT 1 receive)
<----------250 File transfer started
BYE CRLF ----------------->
<----------252 File transfer completed
c) HOST X closes the TELNET and data connections.
Note: The TIP user should be in line mode.
2. User at HOST U wanting to transfer files to/from HOST S:
In general the user would communicate to the server via a mediat-
ing user-FTP process. The following may be a typical scenario.
The user-FTP prompts are shown in parentheses, '---->' represents
commands from HOST U to HOST S, and '<----' represents replies
from HOST S to HOST U.
Local Commands by User Action Involved
---------------------- ---------------
ftp (host) multics CR ICP to HOST S, socket 3,
establishing TELNET connections.
username Doe CR USER Doe CRLF ---->
<---- 330 password CRLF
password mumble CR PASS mumble CRLF ---->
<---- 230 Doe logged in. CRLF
retrieve (local type) ASCII CR
(local pathname) test 1 CR User-FTP opens local file in ASCII.
(for.pathname) test.p11 CR RETR test.p11 CRLF
<---- 255 SOCK 1233 CRLF
Server makes data connection to (U+4).
<---- 250 File transfer starts CRLF
<---- 252 File transfer complete CRLF
type ImageCR TYPE I CRLF ---->
<---- 200 Command OK CRLF
byte 36CR BYTE 36 CRLF ---->
<---- 200 Command OK CRLF
store (local type) image CR
(local pathname) file dump CR User-FTP opens local file in Image.
(for.pathname) >udd>cn>fd CR STOR >udd>cn>fd CRLF ---->
<---- 451 Access denied CRLF
terminate <---- 231 Doe logged out CRLF
Server closes all connections.
[ This RFC was put into machine readable form for entry ]
[ into the online RFC archives by Via Genie 03/00 ]