Rfc | 3970 |
Title | A Traffic Engineering (TE) MIB |
Author | K. Kompella |
Date | January 2005 |
Format: | TXT, HTML |
Updated by | RFC9141 |
Status: | PROPOSED STANDARD |
|
Network Working Group K. Kompella
Request for Comments: 3970 Juniper Networks
Category: Standards Track January 2005
A Traffic Engineering (TE) MIB
Status of This Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Copyright Notice
Copyright (C) The Internet Society (2005).
Abstract
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in the Internet community.
In particular, it describes managed objects for Traffic Engineered
(TE) Tunnels; for example, Multi-Protocol Label Switched Paths.
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1. Specification of Requirements. . . . . . . . . . . . . . 2
2. The Internet-Standard Management Framework . . . . . . . . . . 2
3. Overview of the MIB Module . . . . . . . . . . . . . . . . . . 2
3.1. Traffic Engineering Information. . . . . . . . . . . . . 3
3.2. Traffic Tunnel Information . . . . . . . . . . . . . . . 3
3.3. Path Information . . . . . . . . . . . . . . . . . . . . 3
3.4. Hop Information. . . . . . . . . . . . . . . . . . . . . 4
3.5. Relationship with Other MIB Modules. . . . . . . . . . . 4
4. Creating, Modifying, and Deleting a TE Tunnel. . . . . . . . . 4
5. MIB Specification. . . . . . . . . . . . . . . . . . . . . . . 5
6. References . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6.1. Normative References . . . . . . . . . . . . . . . . . . 40
6.2. Informative References . . . . . . . . . . . . . . . . . 40
7. Security Considerations. . . . . . . . . . . . . . . . . . . . 41
Acknowledgments. . . . . . . . . . . . . . . . . . . . . . . . . . 42
Author's Address . . . . . . . . . . . . . . . . . . . . . . . . . 43
Full Copyright Statement . . . . . . . . . . . . . . . . . . . . . 44
1. Introduction
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in the Internet community.
In particular, it describes managed objects for Traffic Engineered
(TE) Tunnels; for example, Multi-Protocol Label Switched Paths ([7],
[8]). The MIB module defined by this memo allows one to configure TE
Tunnels, to assign one or more paths to a Tunnel, and to monitor
operational aspects of the Tunnel, such as the number of octets and
packets that have passed through the Tunnel.
As it stands, this MIB module can only be used to configure or
monitor a TE Tunnel at its ingress. The ingress is then expected to
use some protocol (such as RSVP-TE) to signal the other routers in
the path the information they need to set up the tunnel. The
extension of this module for use at other points of a Tunnel is for
further study.
1.1. Specification of Requirements
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in RFC 2119 [1].
2. The Internet-Standard Management Framework
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to Section 7 of
RFC 3410 [8].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. MIB objects are generally
accessed through the Simple Network Management Protocol (SNMP).
Objects in the MIB are defined using the mechanisms defined in the
Structure of Management Information (SMI). This memo specifies a MIB
module that is compliant to the SMIv2, which is described in STD 58,
RFC 2578 [2], STD 58, RFC 2579 [3] and STD 58, RFC 2580 [4].
3. Overview of the MIB Module
The Traffic Engineering MIB module consists of four parts:
1) Traffic Engineering information,
2) a table of Traffic Engineering Tunnels,
3) a table of Paths that tunnels take, and
4) a table of Hops that make up a tunnel path.
The MIB module also has statements for minimal and full compliance.
The following subsections give an overview of each part. All objects
are mandatory. For minimal compliance, all objects MAY be
implemented read-only; for full compliance, all objects must be
implemented to their stated MAX-ACCESS capabilities. Notifications
are optional.
3.1. Traffic Engineering Information
This part contains information about the Link State Protocols used to
carry TE information, the signaling protocols used to set up Traffic
Tunnels, the number of Traffic Tunnels that have been configured and
that are operational, and a mapping of Administrative Group (called
Resource Classes in [7]) numbers to names.
3.2. Traffic Tunnel Information
This part contains a table of Traffic Tunnels and information about
each one. This information includes the Tunnel name, its
configuration information, its operational information, and the
active path(s) that the Tunnel takes.
Configuration information includes the end points of the Traffic
Tunnel, and the number of configured paths for the Traffic Tunnel.
Operational information includes the current state (up/down), the
count of octets and packets sent on the Traffic Tunnel, how long it
has been up, and how many state transitions the Traffic Tunnel has
had.
Operational path information includes the number of operational
paths, the number of path changes, and when the last path change was.
3.3. Path Information
A Tunnel is a logical entity. An instantiation of a Tunnel is one or
more Paths; each Path has a route (also called Explicit Route) or
sequence of hops. A Path is indexed by a dual index: The primary
index is that of the Tunnel to which the Path belongs; the secondary
index is that of the Path itself.
The configured information for a Path consists of the constraints for
the Path and a configured route.
The operational information consists of the Path status, the computed
route (i.e., the route that was computed to satisfy the constraints),
and the actual path as recorded by the signaling protocol.
3.4. Hop Information
A path consists of a sequence of hops. A hop can be loose (meaning
that the path eventually traverses the specified node) or strict
(meaning that the specified node and possibly the link must be the
next node in the path). A hop can be specified as an IPv4 address,
an IPv6 address, an Autonomous System number or an unnumbered
interface index [5].
The Hop Table contains all hops for all paths on a given router. It
is organized as follows. There is a primary index that identifies a
list of hops and a secondary index that identifies individual hops.
Thus, to get the sequence of recorded hops for a path, one looks up
the path's tePathRecordedRoute, which is a primary index into the Hop
Table. Then to get the list of actual hops in order for the recorded
path, one uses a secondary index of 1, 2, ....
3.5. Relationship with Other MIB Modules
A TE Tunnel can extend objects from two other MIB modules; one is the
Interfaces MIB [10], and the other is the IP Tunnel MIB [11]. The
mechanism for doing so is to assign the TE Tunnel index
(teTunnelIndex) with a valid ifIndex value in ifTable.
If a TE Tunnel is deemed an interface, a new interface object is
created and assigned an ifIndex value in ifTable. Then a TE Tunnel
object is created, setting teTunnelIndex to the same value as the
interface index.
If (and only if) a TE Tunnel is considered an interface, it may also
be considered an IP tunnel (if the encapsulation of the TE Tunnel is
IP). In that case, the interface associated with the TE Tunnel
should have its ifType set to tunnel(131).
If a TE Tunnel is not considered an interface, then the TE Tunnel
index (teTunnelIndex) SHOULD be set to a value at least 2^24, so that
it is distinct from normal interfaces.
4. Creating, Modifying, and Deleting a TE Tunnel
To create a TE Tunnel, one first obtains a free Tunnel index by using
the object teNextTunnelIndex. One then creates the Tunnel, including
all parameters, either as createAndGo or createAndWait. Then, TE
Paths for this Tunnel can be created by using the
teTunnelNextPathIndex object, again as createAndGo or createAndWait.
A particular Path is computed and signaled when both the Path and the
enclosing Tunnel have RowStatus 'active'.
To build a Path's configured route, one first gets a free PathHop
index by using teNextPathHopIndex, and then builds the route hop-by-
hop using the secondary index, setting the AddrType, Address, and
HopType for each Hop. Finally, one sets the tePathConfiguredRoute in
the Path to the PathHop index obtained.
Modifying certain properties of a TE Tunnel or a TE Path may require
setting the RowStatus of the Tunnel (or Path) to 'notInService'
before making the changes and then setting the RowStatus of the
Tunnel (or Path) back to 'active' to re-signal all Paths of the
Tunnel (or the modified Path).
A TE Tunnel and all its Paths can be deleted by setting the Tunnel's
RowStatus to 'destroy'. A specific Path within a Tunnel can be
destroyed by setting that Path's RowStatus to 'destroy'.
5. MIB Specification
This MIB module IMPORTs objects from RFCs 2578 [2], 2579 [3], 2580
[3], 3411 [6], and 3811 [5] and it also has REFERENCE clauses to RFCs
3209 [8] and 3212 [12].
TE-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE, mib-2,
Integer32, Gauge32, Counter32,
Counter64, Unsigned32, TimeTicks FROM SNMPv2-SMI
RowStatus, StorageType, TimeStamp,
TruthValue FROM SNMPv2-TC
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF
TeHopAddress, TeHopAddressType,
MplsBitRate FROM MPLS-TC-STD-MIB;
teMIB MODULE-IDENTITY
LAST-UPDATED "200501040000Z" -- 01 January 2005
ORGANIZATION "IETF Traffic Engineering Working Group"
CONTACT-INFO "
Editor: Kireeti Kompella
Postal: Juniper Networks, Inc.
1194 Mathilda Ave
Sunnyvale, CA 94089
Tel: +1 408 745 2000
E-mail: kireeti@juniper.net
The IETF Traffic Engineering Working Group is
chaired by Jim Boyle and Ed Kern.
WG Mailing List information:
General Discussion: te-wg@ops.ietf.org
To Subscribe: te-wg-request@ops.ietf.org
In Body: subscribe
Archive: ftp://ops.ietf.org/pub/lists
Comments on the MIB module should be sent to the
mailing list. The archives for this mailing list
should be consulted for previous discussion on
this MIB.
"
DESCRIPTION "The Traffic Engineering MIB module.
Copyright (C) The Internet Society (2005). This
version of this MIB module is part of RFC 3970;
see the RFC itself for full legal notices.
"
-- revision history
REVISION "200501040000Z" -- 01 January 2005
DESCRIPTION "Initial version, published as RFC 3970."
::= { mib-2 122 }
-- Top level objects
teMIBNotifications OBJECT IDENTIFIER ::= { teMIB 0 }
teMIBObjects OBJECT IDENTIFIER ::= { teMIB 1 }
teMIBConformance OBJECT IDENTIFIER ::= { teMIB 2 }
-- ****************************************************************
--
-- TE MIB Objects
--
-- TE Info
teInfo OBJECT IDENTIFIER ::= { teMIBObjects 1 }
teDistProtocol OBJECT-TYPE
SYNTAX BITS {
other(0),
isis(1),
ospf(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "IGP used to distribute Traffic Engineering
information and topology to each device for the
purpose of automatic path computation. More than
one IGP may be used to distribute TE information.
"
::= { teInfo 1 }
teSignalingProto OBJECT-TYPE
SYNTAX BITS {
other(0),
rsvpte(1),
crldp(2),
static(3) -- static configuration
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Traffic Engineering signaling protocols supported
by this device. More than one protocol may be
supported.
"
REFERENCE "For a description of RSVP-TE, see RFC 3209;
for CR-LDP, see RFC 3212.
"
::= { teInfo 2 }
teNotificationEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "If this object is true, then it enables the
generation of notifications from this MIB module.
Otherwise notifications are not generated.
"
DEFVAL { false }
::= { teInfo 3 }
teNextTunnelIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An integer that may be used as a new Index in the
teTunnelTable.
The special value of 0 indicates that no more new
entries can be created in that table.
When this MIB module is used for configuration, this
object always contains a legal value (if non-zero)
for an index that is not currently used in that
table. The Command Generator (Network Management
Application) reads this variable and uses the
(non-zero) value read when creating a new row with
an SNMP SET. When the SET is performed, the Command
Responder (agent) must determine whether the value
is indeed still unused; Two Network Management
Applications may attempt to create a row
(configuration entry) simultaneously and use the
same value. If it is currently unused, the SET
succeeds, and the Command Responder (agent) changes
the value of this object according to an
implementation-specific algorithm. If the value is
in use, however, the SET fails. The Network
Management Application must then re-read this
variable to obtain a new usable value.
"
::= { teInfo 4 }
teNextPathHopIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An integer that may be used as a new Index in the
tePathHopTable.
The special value of 0 indicates that no more new
entries can be created in that table.
When this MIB module is used for configuration, this
object always contains a legal value (if non-zero)
for an index that is not currently used in that
table. The Command Generator (Network Management
Application) reads this variable and uses the
(non-zero) value read when creating a new row with
an SNMP SET. When the SET is performed, the Command
Responder (agent) must determine whether the value
is indeed still unused; Two Network Management
Applications may attempt to create a row
(configuration entry) simultaneously and use the
same value. If it is currently unused, the SET
succeeds, and the Command Responder (agent) changes
the value of this object according to an
implementation-specific algorithm. If the value is
in use, however, the SET fails. The Network
Management Application must then re-read this
variable to obtain a new usable value.
"
::= { teInfo 5 }
teConfiguredTunnels OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of currently configured Tunnels."
::= { teInfo 6 }
teActiveTunnels OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of currently active Tunnels."
::= { teInfo 7 }
tePrimaryTunnels OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of currently active Tunnels running on
their primary paths.
"
::= { teInfo 8 }
teAdminGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF TeAdminGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A mapping of configured administrative groups. Each
entry represents an Administrative Group and
provides a name and index for the group.
Administrative groups are used to label links in the
Traffic Engineering topology in order to place
constraints (include and exclude) on Tunnel paths.
A groupName can only be linked to one group number.
The groupNumber is the number assigned to the
administrative group used in constraints,
such as tePathIncludeAny or tePathIncludeAll.
"
::= { teInfo 9 }
teAdminGroupEntry OBJECT-TYPE
SYNTAX TeAdminGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A mapping between a configured group number and
its human-readable name. The group number should
be between 1 and 32, inclusive. Group number n
represents bit number (n-1) in the bit vector for
Include/Exclude constraints.
All entries in this table MUST be kept in stable
storage so that they will re-appear in case of a
restart/reboot.
"
INDEX { teAdminGroupNumber }
::= { teAdminGroupTable 1 }
TeAdminGroupEntry ::=
SEQUENCE {
teAdminGroupNumber Integer32,
teAdminGroupName SnmpAdminString,
teAdminGroupRowStatus RowStatus
}
teAdminGroupNumber OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Index of the administrative group."
::= { teAdminGroupEntry 1 }
teAdminGroupName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Name of the administrative group."
::= { teAdminGroupEntry 2 }
teAdminGroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this conceptual row.
The value of this object has no effect on whether
other objects in this conceptual row can be
modified.
"
::= { teAdminGroupEntry 3 }
-- Tunnel Table
teTunnelTable OBJECT-TYPE
SYNTAX SEQUENCE OF TeTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of Configured Traffic Tunnels."
::= { teMIBObjects 2 }
teTunnelEntry OBJECT-TYPE
SYNTAX TeTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing information about a particular
Traffic Tunnel.
"
INDEX { teTunnelIndex }
::= { teTunnelTable 1 }
TeTunnelEntry ::=
SEQUENCE {
teTunnelIndex Unsigned32,
teTunnelName SnmpAdminString,
teTunnelNextPathIndex Unsigned32,
-- Conceptual row information:
teTunnelRowStatus RowStatus,
teTunnelStorageType StorageType,
-- Address information:
teTunnelSourceAddressType TeHopAddressType,
teTunnelSourceAddress TeHopAddress,
teTunnelDestinationAddressType TeHopAddressType,
teTunnelDestinationAddress TeHopAddress,
-- State/performance information:
teTunnelState INTEGER,
teTunnelDiscontinuityTimer TimeStamp,
teTunnelOctets Counter64,
teTunnelPackets Counter64,
teTunnelLPOctets Counter32,
teTunnelLPPackets Counter32,
teTunnelAge TimeTicks,
teTunnelTimeUp TimeTicks,
teTunnelPrimaryTimeUp TimeTicks,
teTunnelTransitions Counter32,
teTunnelLastTransition TimeTicks,
teTunnelPathChanges Counter32,
teTunnelLastPathChange TimeTicks,
teTunnelConfiguredPaths Gauge32,
teTunnelStandbyPaths Gauge32,
teTunnelOperationalPaths Gauge32
}
teTunnelIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A unique index that identifies a Tunnel. If the TE
Tunnel is considered an interface, then this index
must match the interface index of the corresponding
interface. Otherwise, this index must be at least
2^24, so that it does not overlap with any existing
interface index.
"
::= { teTunnelEntry 1 }
teTunnelName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Name of the Traffic Tunnel.
Note that the name of a Tunnel MUST be unique.
When a SET request contains a name that is already
in use for another entry, then the implementation
must return an inconsistentValue error.
The value of this object cannot be changed if the
if the value of the corresponding teTunnelRowStatus
object is 'active'.
"
::= { teTunnelEntry 2 }
teTunnelNextPathIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An integer that may be used as a new Index for the
next Path in this Tunnel.
The special value of 0 indicates that no more Paths
can be created for this Tunnel, or that no more new
entries can be created in tePathTable.
When this MIB module is used for configuration, this
object always contains a legal value (if non-zero)
for an index that is not currently used in that
table. The Command Generator (Network Management
Application) reads this variable and uses the
(non-zero) value read when creating a new row with
an SNMP SET. When the SET is performed, the Command
Responder (agent) must determine whether the value
is indeed still unused; Two Network Management
Applications may attempt to create a row
(configuration entry) simultaneously and use the
same value. If it is currently unused, the SET
succeeds, and the Command Responder (agent) changes
the value of this object according to an
implementation-specific algorithm. If the value is
in use, however, the SET fails. The Network
Management Application must then re-read this
variable to obtain a new usable value.
"
::= { teTunnelEntry 3 }
teTunnelRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this conceptual row.
When the value of this object is 'active', then
the values for the corresponding objects
teTunnelName, teTunnelSourceAddressType,
teTunnelSourceAddress,
teTunnelDestinationAddressType, and
teTunnelDestinationAddress cannot be changed.
"
::= { teTunnelEntry 4 }
teTunnelStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The storage type for this conceptual row.
Conceptual rows having the value 'permanent' need
not allow write-access to any columnar objects
in the row.
"
::= { teTunnelEntry 5 }
teTunnelSourceAddressType OBJECT-TYPE
SYNTAX TeHopAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of Traffic Engineered Tunnel hop address
for the source of this Tunnel. Typically, this
address type is IPv4 or IPv6, with a prefix length
of 32 or 128, respectively. If the TE Tunnel path
is being computed by a path computation server,
however, it is possible to use more flexible source
address types, such as AS numbers or prefix lengths
less than host address lengths.
The value of this object cannot be changed
if the value of the corresponding teTunnelRowStatus
object is 'active'.
"
::= { teTunnelEntry 6 }
teTunnelSourceAddress OBJECT-TYPE
SYNTAX TeHopAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Source Traffic Engineered Tunnel hop address of
this Tunnel.
The type of this address is determined by the value
of the corresponding teTunnelSourceAddressType.
Note that the source and destination addresses of a
Tunnel can be different address types.
The value of this object cannot be changed
if the value of the corresponding teTunnelRowStatus
object is 'active'.
"
::= { teTunnelEntry 7 }
teTunnelDestinationAddressType OBJECT-TYPE
SYNTAX TeHopAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of Traffic Engineered Tunnel hop address
for the destination of this Tunnel.
The value of this object cannot be changed
if the value of the corresponding teTunnelRowStatus
object is 'active'.
"
::= { teTunnelEntry 8 }
teTunnelDestinationAddress OBJECT-TYPE
SYNTAX TeHopAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Destination Traffic Engineered Tunnel hop
address of this Tunnel.
The type of this address is determined by the value
of the corresponding teTunnelDestinationAddressType.
Note that source and destination addresses of a
Tunnel can be different address types.
The value of this object cannot be changed
if the value of the corresponding teTunnelRowStatus
object is 'active'.
"
::= { teTunnelEntry 9 }
teTunnelState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
up(2),
down(3),
testing(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The operational state of the Tunnel."
::= { teTunnelEntry 10 }
teTunnelDiscontinuityTimer OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of sysUpTime on the most recent occasion
at which any one or more of this tunnel's counters
suffered a discontinuity. The relevant counters
are teTunnelOctets, teTunnelPackets,
teTunnelLPOctets, and teTunnelLPPackets. If no such
discontinuities have occurred since the last
re-initialization of the local management subsystem
then this object contains a zero value.
"
::= { teTunnelEntry 11 }
teTunnelOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of octets that have been forwarded over
the Tunnel.
Discontinuities in the value of this counter can
occur at re-initialization of the management system,
and at other times, as indicated by the value of
teTunnelDiscontinuityTimer.
"
::= { teTunnelEntry 12 }
teTunnelPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of packets that have been forwarded over
the Tunnel.
Discontinuities in the value of this counter can
occur at re-initialization of the management system
and at other times, as indicated by the value of
teTunnelDiscontinuityTimer.
"
::= { teTunnelEntry 13 }
teTunnelLPOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of octets that have been forwarded over
the Tunnel.
Discontinuities in the value of this counter can
occur at re-initialization of the management system
and at other times, as indicated by the value of
teTunnelDiscontinuityTimer.
"
::= { teTunnelEntry 14 }
teTunnelLPPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of packets that have been forwarded over
the Tunnel.
Discontinuities in the value of this counter can
occur at re-initialization of the management system
and at other times, as indicated by the value of
teTunnelDiscontinuityTimer.
"
::= { teTunnelEntry 15 }
teTunnelAge OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The age (i.e., time from creation of this conceptual
row till now) of this Tunnel in hundredths of a
second. Note that because TimeTicks wrap in about
16 months, this value is best used in interval
measurements.
"
::= { teTunnelEntry 16 }
teTunnelTimeUp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total time in hundredths of a second that this
Tunnel has been operational. Note that because
TimeTicks wrap in about 16 months, this value is
best used in interval measurements.
An example of usage of this object would be to
compute the percentage up time over a period of time
by obtaining values of teTunnelAge and
teTunnelTimeUp at two points in time and computing
the following ratio:
((teTunnelTimeUp2 - teTunnelTimeUp1)/
(teTunnelAge2 - teTunnelAge1)) * 100 %. In doing
so, the management station must account for
wrapping of the values of teTunnelAge and
teTunnelTimeUp between the two measurements.
"
::= { teTunnelEntry 17 }
teTunnelPrimaryTimeUp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total time in hundredths of a second that this
Tunnel's primary path has been operational. Note
that because TimeTicks wrap in about 16 months, this
value is best used in interval measurements.
An example of usage of this field would be to
compute what percentage of time that a TE Tunnel was
on the primary path over a period of time by
computing
((teTunnelPrimaryTimeUp2 - teTunnelPrimaryTimeUp1)/
(teTunnelTimeUp2 - teTunnelTimeUp1))*100 %. In
doing so, the management station must account for
wrapping of the values of teTunnelPrimaryTimeUp and
teTunnelTimeUp between the two measurements.
"
::= { teTunnelEntry 18 }
teTunnelTransitions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of operational state transitions
(up -> down and down -> up) this Tunnel has
undergone.
"
::= { teTunnelEntry 19 }
teTunnelLastTransition OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time in hundredths of a second since the last
operational state transition occurred on this
Tunnel.
Note that if the last transition was over 16
months ago, this value will be inaccurate.
"
::= { teTunnelEntry 20 }
teTunnelPathChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of path changes this Tunnel has had."
::= { teTunnelEntry 21 }
teTunnelLastPathChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time in hundredths of a second since the last
path change occurred on this Tunnel.
Note that if the last transition was over 16
months ago, this value will be inaccurate.
Path changes may be caused by network events or by
reconfiguration that affects the path.
"
::= { teTunnelEntry 22 }
teTunnelConfiguredPaths OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of paths configured for this Tunnel."
::= { teTunnelEntry 23 }
teTunnelStandbyPaths OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of standby paths configured for this
Tunnel.
"
::= { teTunnelEntry 24 }
teTunnelOperationalPaths OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of operational paths for this Tunnel.
This includes the path currently active, as
well as operational standby paths.
"
::= { teTunnelEntry 25 }
-- ****************************************************************
--
-- Tunnel Path Table
--
tePathTable OBJECT-TYPE
SYNTAX SEQUENCE OF TePathEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of Configured Traffic Tunnels."
::= { teMIBObjects 3 }
tePathEntry OBJECT-TYPE
SYNTAX TePathEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing information about a particular
Traffic Tunnel. Each Traffic Tunnel can have zero
or more Traffic Paths.
As a Traffic Path can only exist over an existing
Traffic Tunnel, all tePathEntries with
a value of n for teTunnelIndex MUST be removed by
the implementation when the corresponding
teTunnelEntry with a value of n for teTunnelIndex
is removed.
"
INDEX { teTunnelIndex, tePathIndex }
::= { tePathTable 1 }
TePathEntry ::=
SEQUENCE {
tePathIndex Unsigned32,
tePathName SnmpAdminString,
-- Conceptual row information
tePathRowStatus RowStatus,
tePathStorageType StorageType,
-- Path properties
tePathType INTEGER,
tePathConfiguredRoute Unsigned32,
tePathBandwidth MplsBitRate,
tePathIncludeAny Unsigned32,
tePathIncludeAll Unsigned32,
tePathExclude Unsigned32,
tePathSetupPriority Integer32,
tePathHoldPriority Integer32,
tePathProperties BITS,
-- Path status
tePathOperStatus INTEGER,
tePathAdminStatus INTEGER,
tePathComputedRoute Unsigned32,
tePathRecordedRoute Unsigned32
}
tePathIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index that uniquely identifies a path within
a Tunnel.
The combination of <teTunnelIndex, tePathIndex> thus
uniquely identifies a path among all paths on this
router.
"
::= { tePathEntry 1 }
tePathName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The name of this path.
A pathName must be unique within the set of paths
over a single tunnel. If a SET request is received
with a duplicate name, then the implementation MUST
return an inconsistentValue error.
The value of this object cannot be changed
if the value of the corresponding teTunnelRowStatus
object is 'active'.
"
::= { tePathEntry 2 }
tePathRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this conceptual row.
When the value of this object is 'active', then
the value of tePathName cannot be changed. All
other writable objects may be changed; however,
these changes may affect traffic going over the TE
tunnel or require the path to be computed and/or
re-signaled.
"
::= { tePathEntry 3 }
tePathStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The storage type for this conceptual row.
Conceptual rows having the value 'permanent' need
not allow write-access to any columnar objects
in the row.
"
::= { tePathEntry 4 }
tePathType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
primary(2),
standby(3),
secondary(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type for this PathEntry; i.e., whether this path
is a primary path, a standby path, or a secondary
path.
"
::= { tePathEntry 5 }
tePathConfiguredRoute OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The route that this TE path is configured to follow;
i.e., an ordered list of hops. The value of this
object gives the primary index into the Hop Table.
The secondary index is the hop count in the path, so
to get the route, one could get the first hop with
index <tePathConfiguredRoute, 1> in the Hop Table
and do a getnext to get subsequent hops.
"
::= { tePathEntry 6 }
tePathBandwidth OBJECT-TYPE
SYNTAX MplsBitRate
UNITS "Kilobits per second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The configured bandwidth for this Tunnel,
in units of thousands of bits per second (Kbps).
"
DEFVAL { 0 }
::= { tePathEntry 7 }
tePathIncludeAny OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This is a configured set of administrative groups
specified as a bit vector (i.e., bit n is 1 if group
n is in the set, where n = 0 is the LSB). For each
link that this path goes through, the link must have
at least one of the groups specified in IncludeAny
to be acceptable. If IncludeAny is zero, all links
are acceptable.
"
DEFVAL { 0 }
::= { tePathEntry 8 }
tePathIncludeAll OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This is a configured set of administrative groups
specified as a bit vector (i.e., bit n is 1 if group
n is in the set, where n = 0 is the LSB). For each
link that this path goes through, the link must have
all of the groups specified in IncludeAll to be
acceptable. If IncludeAll is zero, all links are
acceptable.
"
DEFVAL { 0 }
::= { tePathEntry 9 }
tePathExclude OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This is a configured set of administrative groups
specified as a bit vector (i.e., bit n is 1 if group
n is in the set, where n = 0 is the LSB). For each
link that this path goes through, the link MUST have
groups associated with it, and the intersection of
the link's groups and the 'exclude' set MUST be
null.
"
DEFVAL { 0 }
::= { tePathEntry 10 }
tePathSetupPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The setup priority configured for this path, with 0
as the highest priority and 7 as the lowest.
"
DEFVAL { 7 }
::= { tePathEntry 11 }
tePathHoldPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The hold priority configured for this path, with 0
as the highest priority and 7 as the lowest.
"
DEFVAL { 0 }
::= { tePathEntry 12 }
tePathProperties OBJECT-TYPE
SYNTAX BITS {
recordRoute(0),
cspf(1),
makeBeforeBreak(2),
mergeable(3),
fastReroute(4),
protected(5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The set of configured properties for this path,
expressed as a bit map. For example, if the path
supports 'make before break', then bit 2 is set.
"
::= { tePathEntry 13 }
tePathOperStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
down(1),
testing(2),
dormant(3),
ready(4),
operational(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The operational status of the path:
unknown:
down: Signaling failed.
testing: Administratively set aside for testing.
dormant: Not signaled (for a backup tunnel).
ready: Signaled but not yet carrying traffic.
operational: Signaled and carrying traffic.
"
::= { tePathEntry 14 }
tePathAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
testing(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The operational status of the path:
normal: Used normally for forwarding.
testing: Administratively set aside for testing.
"
::= { tePathEntry 15 }
tePathComputedRoute OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The route computed for this path, perhaps using
some form of Constraint-based Routing. The
algorithm is implementation dependent.
This object returns the computed route as an ordered
list of hops. The value of this object gives the
primary index into the Hop Table. The secondary
index is the hop count in the path, so to get the
route, one could get the first hop with index
<tePathComputedRoute, 1> in the Hop Table and do a
getnext to get subsequent hops.
A value of zero (0) means there is no computedRoute.
"
::= { tePathEntry 16 }
tePathRecordedRoute OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The route actually used for this path, as recorded
by the signaling protocol. This is again an ordered
list of hops; each hop is expected to be strict.
The value of this object gives the primary index
into the Hop Table. The secondary index is the hop
count in the path, so to get the route, one can get
the first hop with index <tePathRecordedRoute, 1>
in the Hop Table and do a getnext to get subsequent
hops.
A value of zero (0) means there is no recordedRoute.
"
::= { tePathEntry 17 }
-- ****************************************************************
--
-- Tunnel Path Hop Table
--
tePathHopTable OBJECT-TYPE
SYNTAX SEQUENCE OF TePathHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of Tunnel Path Hops."
::= { teMIBObjects 4 }
tePathHopEntry OBJECT-TYPE
SYNTAX TePathHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing information about a particular
hop.
"
INDEX { teHopListIndex, tePathHopIndex }
::= { tePathHopTable 1 }
TePathHopEntry ::=
SEQUENCE {
teHopListIndex Unsigned32,
tePathHopIndex Unsigned32,
-- Conceptual row information
tePathHopRowStatus RowStatus,
tePathHopStorageType StorageType,
tePathHopAddrType TeHopAddressType,
tePathHopAddress TeHopAddress,
tePathHopType INTEGER
}
teHopListIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index that identifies a list of hops. This is
the primary index to access hops.
"
::= { tePathHopEntry 1 }
tePathHopIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index that identifies a particular hop among the
list of hops for a path. An index of i identifies
the ith hop. This is the secondary index for a hop
entry.
"
::= { tePathHopEntry 2 }
tePathHopRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this conceptual row.
Any field in this table can be changed, even if the
value of this object is 'active'. However, such a
change may cause traffic to be rerouted or even
disrupted.
"
::= { tePathHopEntry 3 }
tePathHopStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The storage type for this conceptual row.
Conceptual rows having the value 'permanent' need
not allow write-access to any columnar objects
in the row.
"
::= { tePathHopEntry 4 }
tePathHopAddrType OBJECT-TYPE
SYNTAX TeHopAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of Traffic Engineered Tunnel hop Address
of this hop.
The value of this object cannot be changed
if the value of the corresponding tePathRowStatus
object is 'active'.
"
::= { tePathHopEntry 5 }
tePathHopAddress OBJECT-TYPE
SYNTAX TeHopAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Traffic Engineered Tunnel hop Address of this
hop.
The type of this address is determined by the value
of the corresponding tePathHopAddressType.
The value of this object cannot be changed
if the value of the corresponding teTunnelRowStatus
object is 'active'.
"
::= { tePathHopEntry 6 }
tePathHopType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
loose(1),
strict(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of hop:
unknown:
loose: This hop is a LOOSE hop.
strict: This hop is a STRICT hop.
"
::= { tePathHopEntry 7 }
-- ****************************************************************
--
-- TE Notifications
--
teTunnelUp NOTIFICATION-TYPE
OBJECTS { teTunnelName,
tePathName } -- TunnelPath
STATUS current
DESCRIPTION "A teTunnelUp notification is generated when the
Tunnel indexed by teTunnelName transitions to the
'up' state.
A tunnel is up when at least one of its paths is up.
The tePathName is the name of the path whose
transition to up made the tunnel go up.
This notification MUST be limited to at most one
every minute, in case the tunnel flaps up and down.
"
::= { teMIBNotifications 1 }
teTunnelDown NOTIFICATION-TYPE
OBJECTS { teTunnelName,
tePathName } -- TunnelPath
STATUS current
DESCRIPTION "A teTunnelDown notification is generated when the
Tunnel indexed by teTunnelName transitions to the
'down' state.
A tunnel is up when at least one of its paths is up.
The tePathName is the name of the path whose
transition to down made the tunnel go down.
This notification MUST be limited to at most one
every minute, in case the tunnel flaps up and down.
"
::= { teMIBNotifications 2 }
teTunnelChanged NOTIFICATION-TYPE
OBJECTS { teTunnelName,
tePathName } -- toTunnelPath
STATUS current
DESCRIPTION "A teTunnelChanged notification is generated when an
active path on the Tunnel indexed by teTunnelName
changes or a new path becomes active. The value
of tePathName is the new active path.
This notification MUST be limited to at most one
every minute, in case the tunnel changes quickly.
"
::= { teMIBNotifications 3 }
teTunnelRerouted NOTIFICATION-TYPE
OBJECTS { teTunnelName,
tePathName } -- toTunnelPath
STATUS current
DESCRIPTION "A teTunnelRerouted notification is generated when
an active path for the Tunnel indexed by
teTunnelName stays the same, but its route changes.
This notification MUST be limited to at most one
every minute, in case the tunnel reroutes quickly.
"
::= { teMIBNotifications 4 }
-- End of TE-MIB objects
-- ****************************************************************
--
-- TE Compliance Statements
--
teGroups
OBJECT IDENTIFIER ::= { teMIBConformance 1 }
teModuleCompliance
OBJECT IDENTIFIER ::= { teMIBConformance 2 }
-- ****************************************************************
--
-- TE object groups
--
teTrafficEngineeringGroup OBJECT-GROUP
OBJECTS {
teTunnelName,
teTunnelNextPathIndex,
teTunnelRowStatus,
teTunnelStorageType,
teTunnelSourceAddressType,
teTunnelSourceAddress,
teTunnelDestinationAddressType,
teTunnelDestinationAddress,
teTunnelState,
teTunnelDiscontinuityTimer,
teTunnelOctets,
teTunnelPackets,
teTunnelLPOctets,
teTunnelLPPackets,
teTunnelAge,
teTunnelTimeUp,
teTunnelPrimaryTimeUp,
teTunnelTransitions,
teTunnelLastTransition,
teTunnelPathChanges,
teTunnelLastPathChange,
teTunnelConfiguredPaths,
teTunnelStandbyPaths,
teTunnelOperationalPaths,
tePathBandwidth,
tePathIncludeAny,
tePathIncludeAll,
tePathExclude,
tePathSetupPriority,
tePathHoldPriority,
tePathProperties,
tePathOperStatus,
tePathAdminStatus,
tePathComputedRoute,
tePathRecordedRoute,
teDistProtocol,
teSignalingProto,
teNotificationEnable,
teNextTunnelIndex,
teNextPathHopIndex,
teAdminGroupName,
teAdminGroupRowStatus,
teConfiguredTunnels,
teActiveTunnels,
tePrimaryTunnels,
tePathName,
tePathType,
tePathRowStatus,
tePathStorageType,
tePathConfiguredRoute,
tePathHopRowStatus,
tePathHopStorageType,
tePathHopAddrType,
tePathHopAddress,
tePathHopType
}
STATUS current
DESCRIPTION "Objects for Traffic Engineering in this MIB module."
::= { teGroups 1 }
teNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
teTunnelUp,
teTunnelDown,
teTunnelChanged,
teTunnelRerouted
}
STATUS current
DESCRIPTION "Notifications specified in this MIB module."
::= { teGroups 2 }
-- ****************************************************************
--
-- TE compliance statements
--
-- There are four compliance statements: read-only and full
-- compliance for regular TE devices, and read-only and full
-- compliance for path computation servers.
--
teModuleReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "When this MIB module is implemented without support
for read-create (i.e., in read-only mode), then such
an implementation can claim read-only compliance.
Such a device can be monitored but cannot be
configured with this MIB module.
"
MODULE -- enclosing module, i.e., TE-MIB
MANDATORY-GROUPS {
teTrafficEngineeringGroup
}
GROUP teNotificationGroup
DESCRIPTION "Implementation of this group is optional."
OBJECT teNotificationEnable
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teAdminGroupName
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teAdminGroupRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelName
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelStorageType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelSourceAddressType
SYNTAX TeHopAddressType { ipv4(1), ipv6(2) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required. An
implementation is only required to support
IPv4 and IPv6 host addresses."
OBJECT teTunnelSourceAddress
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelDestinationAddressType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelDestinationAddress
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathName
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathStorageType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathConfiguredRoute
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathBandwidth
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathIncludeAny
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathIncludeAll
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathExclude
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathSetupPriority
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHoldPriority
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathProperties
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathAdminStatus
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHopRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHopStorageType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHopAddrType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHopAddress
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
::= { teModuleCompliance 1 }
teModuleFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "When this MIB module is implemented with support for
read-create, then the implementation can claim
full compliance. Such devices can be both
monitored and configured with this MIB module.
"
MODULE -- enclosing module, i.e., TE-MIB
MANDATORY-GROUPS {
teTrafficEngineeringGroup
}
GROUP teNotificationGroup
DESCRIPTION "Implementation of this group is optional."
OBJECT teAdminGroupRowStatus
SYNTAX RowStatus { active(1) }
WRITE-SYNTAX RowStatus { createAndGo(4), destroy(6) }
DESCRIPTION "Support for notInService, createAndWait and
notReady is not required.
"
OBJECT teTunnelRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { active(1), notInService(2),
createAndGo(4), destroy(6)
}
DESCRIPTION "Support for createAndWait and notReady is not
required.
"
OBJECT teTunnelSourceAddressType
SYNTAX TeHopAddressType { ipv4(1), ipv6(2) }
DESCRIPTION "Write access is required. An implementation is
only required to support IPv4 and IPv6 host
addresses.
"
OBJECT tePathRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { active(1), notInService(2),
createAndGo(4), destroy(6)
}
DESCRIPTION "Support for createAndWait and notReady is not
required.
"
OBJECT tePathHopRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { active(1), notInService(2),
createAndGo(4), destroy(6)
}
DESCRIPTION "Support for createAndWait and notReady is not
required.
"
::= { teModuleCompliance 2 }
teModuleServerReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "When this MIB module is implemented by a path
computation server without support for read-create
(i.e., in read-only mode), then the implementation
can claim read-only compliance. Such
a device can be monitored but cannot be
configured with this MIB module.
"
MODULE -- enclosing module, i.e., TE-MIB
MANDATORY-GROUPS {
teTrafficEngineeringGroup
}
GROUP teNotificationGroup
DESCRIPTION "Implementation of this group is optional."
OBJECT teNotificationEnable
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teAdminGroupName
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teAdminGroupRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelName
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelStorageType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelSourceAddressType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required. A path
computation server SHOULD implement all types
of tunnel source address types.
"
OBJECT teTunnelSourceAddress
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelDestinationAddressType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelDestinationAddress
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathName
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathStorageType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathConfiguredRoute
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathBandwidth
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathIncludeAny
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathIncludeAll
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathExclude
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathSetupPriority
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHoldPriority
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathProperties
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathAdminStatus
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHopRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHopStorageType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHopAddrType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHopAddress
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
::= { teModuleCompliance 3 }
teModuleServerFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "When this MIB module is implemented by a path
computation server with support for read-create,
then the implementation can claim full
compliance.
"
MODULE -- enclosing module, i.e., TE-MIB
MANDATORY-GROUPS {
teTrafficEngineeringGroup
}
GROUP teNotificationGroup
DESCRIPTION "Implementation of this group is optional."
OBJECT teAdminGroupRowStatus
SYNTAX RowStatus { active(1) }
WRITE-SYNTAX RowStatus { createAndGo(4), destroy(6) }
DESCRIPTION "Support for notInService, createAndWait, and
notReady is not required.
"
OBJECT teTunnelRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { active(1), notInService(2),
createAndGo(4), destroy(6)
}
DESCRIPTION "Support for createAndWait and notReady is not
required.
"
OBJECT teTunnelSourceAddressType
DESCRIPTION "Write access is required. An implementation
of a path computation server SHOULD support all
types of tunnel source address types.
"
OBJECT tePathRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { active(1), notInService(2),
createAndGo(4), destroy(6)
}
DESCRIPTION "Support for createAndWait and notReady is not
required.
"
OBJECT tePathHopRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { active(1), notInService(2),
createAndGo(4), destroy(6)
}
DESCRIPTION "Support for createAndWait and notReady is not
required.
"
::= { teModuleCompliance 4 }
END
6. References
6.1. Normative References
[1] Bradner, S., "Key words for use in RFCs to Indicate Requirement
Levels", BCP 14, RFC 2119, March 1997.
[2] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Structure of
Management Information Version 2 (SMIv2)", STD 58, RFC 2578,
April 1999.
[3] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Textual
Conventions for SMIv2", STD 58, RFC 2579, April 1999.
[4] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Conformance
Statements for SMIv2", STD 58, RFC 2580, April 1999.
[5] Nadeau, T. and J. Cucchiara, "Definitions of Textual Conventions
(TCs) for Multiprotocol Label Switching (MPLS) Management", RFC
3811, June 2004.
[6] Harrington, D., Presuhn, R., and B. Wijnen, "An Architecture for
Describing Simple Network Management Protocol (SNMP) Management
Frameworks", STD 62, RFC 3411, December 2002.
[7] Awduche, D., Malcolm, J., Agogbua, J., O'Dell, M., and J.
McManus, "Requirements for Traffic Engineering Over MPLS", RFC
2702, September 1999.
6.2. Informative References
[8] Awduche, D., Berger, L., Gan, D., Li, T., Srinivasan, V., and G.
Swallow, "RSVP-TE: Extensions to RSVP for LSP Tunnels", RFC
3209, December 2001.
[9] Case, J., Mundy, R., Partain, D., and B. Stewart, "Introduction
and Applicability Statements for Internet-Standard Management
Framework", RFC 3410, December 2002.
[10] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB",
RFC 2863, June 2000.
[11] Thaler, D., "IP Tunnel MIB", RFC 2667, August 1999.
[12] Jamoussi, B., Andersson, L., Callon, R., Dantu, R., Wu, L.,
Doolan, P., Worster, T., Feldman, N., Fredette, A., Girish, M.,
Gray, E., Heinanen, J., Kilty, T., and A. Malis, "Constraint-
Based LSP Setup using LDP", RFC 3212, January 2002.
7. Security Considerations
This MIB module relates to the configuration and management of
Traffic Engineering tunnels. The unauthorized manipulation of fields
in the tables teAdminGroupTable, teTunnelTable, tePathTable, and
tePathHopTable may lead to tunnel flapping, tunnel paths being
changed, or traffic being disrupted. In addition, if these tables
are read by unauthorized parties, the information can be used to
trace traffic patterns, traffic volumes, and tunnel paths. This may
be considered proprietary and confidential information by some
providers.
There are a number of management objects defined in this MIB module
with a MAX-ACCESS clause of read-write and/or read-create. Such
objects may be considered sensitive or vulnerable in some network
environments. The support for SET operations in a non-secure
environment without proper protection can have a negative effect on
network operations. These are the tables and objects and their
sensitivity/vulnerability:
teAdminGroupTable: Changing this will affect the semantics of include
and exclude constraints, and thus traffic takes unintended routes.
teTunnelTable: Changing this affects many properties of traffic
tunnels.
tePathTable: Changing this affects the constraints (including
bandwidth) of tunnel paths, as well as the status of the path.
tePathHopTable: Changing this affects the route followed by a traffic
tunnel path.
Some of the readable objects in this MIB module (i.e., objects with a
MAX-ACCESS other than not-accessible) may be considered sensitive or
vulnerable in some network environments. It is thus important to
control even GET and/or NOTIFY access to these objects and possibly
to even encrypt the values of these objects when sending them over
the network via SNMP. These are the tables and objects and their
sensitivity/vulnerability:
teTunnelTable: Describes tunnel endpoints and traffic volumes.
tePathTable: Describes path properties.
tePathHopTable: Describes path routes.
SNMP versions prior to SNMPv3 did not include adequate security.
Even if the network itself is secure (for example by using IPSec),
even then, there is no control as to who on the secure network is
allowed to access and GET/SET (read/change/create/delete) the objects
in this MIB module.
It is RECOMMENDED that implementers consider the security features as
provided by the SNMPv3 framework (see [9], section 8), including full
support for the SNMPv3 cryptographic mechanisms (for authentication
and privacy).
Further, deployment of SNMP versions prior to SNMPv3 is NOT
RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of this MIB module is properly configured to give access to
the objects only to those principals (users) that have legitimate
rights to indeed GET or SET (change/create/delete) them.
Acknowledgments
It was Tony Li's suggestion that the author embark on this MIB. Many
thanks to him and to Der-Hwa Gan for their input and help.
Many thanks, too, to Bert Wijnen for his incredible help, both with
improving the correctness, structure, and readability of the MIB
module, and with the text of the RFC. Thanks also to Adrian Farrel
for his detailed review.
Author's Address
Kireeti Kompella
Juniper Networks, Inc.
1194 N. Mathilda Ave
Sunnyvale, CA 94089
EMail: kireeti@juniper.net
Full Copyright Statement
Copyright (C) The Internet Society (2005).
This document is subject to the rights, licenses and restrictions
contained in BCP 78, and except as set forth therein, the authors
retain all their rights.
This document and the information contained herein are provided on an
"AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Intellectual Property
The IETF takes no position regarding the validity or scope of any
Intellectual Property Rights or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; nor does it represent that it has
made any independent effort to identify any such rights. Information
on the IETF's procedures with respect to rights in IETF Documents can
be found in BCP 78 and BCP 79.
Copies of IPR disclosures made to the IETF Secretariat and any
assurances of licenses to be made available, or the result of an
attempt made to obtain a general license or permission for the use of
such proprietary rights by implementers or users of this
specification can be obtained from the IETF on-line IPR repository at
http://www.ietf.org/ipr.
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights that may cover technology that may be required to implement
this standard. Please address the information to the IETF at ietf-
ipr@ietf.org.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.